Components

Construction assembly D1233

Lignum ID-№
D1233
Catalog number
D.1.01.AW.60.HL_GF/GF
Source of construction assembly
23-073-1 PB Pfleiderer Wand Typ02_4-11, Year 2024
Base structure
Stud
Type of facade
Ventilated facade
Paneling
Without covering
Construction height
244 mm
Weight
72 kg/m2
U-value
≈ 0.196 W/m2K
GWP
30.30 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside twice sheathed, roomside double sheathed. Without covering. Ventilated facade.
Values of airborne sound insulation
Rw 46 dB
C -2 dB
Ctr -7 dB

Comment Montagefuge mit Dichtungsmasse innen- und aussenseitig. Schallschutz geprüft mit KVH 60/140 und Gipsfaserplatte 12,5 mm. Der Einsatz der geeigneten Dampfbremse und der Fassadenbahn ist Projektbezogen zu klären.

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement MFPA Leipzig 27 23 26 26 27 27 28 37 38 40 43 45 49 52 55 56 54 51 54 60 65
Calculation Lignum/Kühn and Blickle 14 17 19 22 25 27 29 29 31 34 37 40 42 44 45 45 45 54 63 70 79 88

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
51572
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
45081
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6480
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
298.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
292.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
141.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
150.80
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.40
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
161.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
160.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
32.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
128.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.40
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
137.70
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
131.50
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
109.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
22.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.00
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
30.30
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
26.50
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.70
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
59.40
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
16.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)